Over 10 years ago, when we were doing our first electronic medical record
(EMR) implementation, we predicted that wrong patient errors would likely
increase as EMR adoption became more widespread (see our May 20, 2008 CPOE Unintended Consequences Are Wrong Patient
Errors More Common?).
One of the reasons we identified was the ability to have the record of more
than one patient open simultaneously. Back then, the major problem was that
multiple IT systems were not yet integrated. So, it was possible to have one
patient record open on a CPOE system and that of another open in a separate lab
IT system or radiology PACS system. But, even as EMRs became more integrated,
some systems allowed users to have open records of more than one patient at a
time.
The Joint Commission (TJC 2015) and the Office of the National Coordinator for Health Information Technology (ONC 2016) have agreed with us and recommended that the number of open EMR records be restricted to one record.
A recent study by Adelman and colleagues, whose work we have referenced in so many of our columns, has challenged that concept. The researchers (Adelman 2019) took advantage of a rollout of a new EMR to randomize users to being restricted to one open record at a time vs being allowed to have as many as four records open simultaneously. They then used their RAR (Retract-and-Reorder) methodology (see our July 17, 2012 Patient Safety Tip of the Week More on Wrong-Patient CPOE) to identify instances where a user initially entered an order on the wrong patient. The RAR methodology is also nicely described in the supplement to the current Adelman study. It is a tool weve recommended you use in tracking and monitoring patient misidentification issues as part of your quality improvement program (see our March 26, 2019 Patient Safety Tip of the Week Patient Misidentification). The RAR methodology, of course, measures near misses (by definition, it identifies instances where the user recognized the error and corrected it). But it is one of the only proxies we have for assessing the frequency of potential wrong-patient ordering errors.
Overall, there was no significant difference in wrong-patient order sessions per 100,000 in the restricted vs unrestricted group, or in any setting. However, in the unrestricted group overall, 66.2% of the order sessions were completed with 1 record open, thereby limiting the power of the study to detect a treatment effect. Furthermore, when they did a post hoc analysis of order sessions in the unrestricted group, the number of wrong-patient order sessions completed with 1 record open was 52.0 per 100,000 order sessions, 132.0 per 100,000 with 2 records open, 165.7 per 100,000 with 3 records open, and 184.5 per 100,000 with 4 records open. Those results were also statistically significant.
In the accompanying editorial (Wachter 2019), Wachter et al. note there are confounders in this issue. One is that circumstances in which a user might want more than one record open are also ones that might engender errors. In complex healthcare environments workload and multitasking may be more important factors contributing to errors. They also remind us that we need to consider unintended consequences and look at the whole picture. An example they give is someone entering a complex heparin titration order who is interrupted for an urgent need for an analgesic on another patient. Closing one record, opening another, then reopening the first record could lead to errors that are not wrong-patient errors. Such tradeoffs between safety and efficiency have been a topic of many of our columns (see, for example, our Patient Safety Tip of the Week ETTOs: Efficiency-Thoroughness Trade-Offs).
Both the Adelman researchers and the editorialists seem reassured that the trial had sufficient power to test the primary question of whether a restricted vs unrestricted configuration reduces wrong-patient orders and that the less restrictive approach (allowing multiple records to be open simultaneously) does not lead to an overall increase in wrong-patient orders.
We dont agree. Most of the points made in the editorial are ones we do agree with and have often discussed in our columns. But the major problem with the Adelman study is akin to the argument weve made in the overlapping surgery debate: the sheer size of the data buries the important findings. The sheer volume of instances where only one record was open dilutes out the findings that occurred when multiple records were open. It is hard to ignore the post-hoc analysis that has what we consider to be the most important facet of this study. It clearly shows that there is an increase in wrong-patient orders when multiple records are open simultaneously and this phenomenon occurs in a dose-dependent fashion.
We hope the study does not open the door to widespread adoption of the less restrictive policy. And, if healthcare systems do start to allow multiple records to be open at the same time, they should incorporate the RAR methodology as part of their quality improvement activities to monitor and track for patient misidentification errors.
We hope youll go back to our March 26, 2019 Patient Safety Tip of the Week Patient Misidentification to review the multitude of issues related to wrong-patient events and what you should be doing to reduce the risks of such events in your organizations.
See some of our other
Patient Safety Tip of the Week columns dealing with unintended consequences of
technology and other healthcare IT issues:
·
December
11, 2018 Another
NMBA Accident
·
January
1, 2019 More
on Automated Dispensing Cabinet (ADC) Safety
·
February
5, 2019 Flaws
in Our Medication Safety Technologies
·
March
26, 2019 Patient Misidentification
·
May 2019
Too
Much Time on the EMR
References:
Adelman JS, Applebaum JR, Schechter CB, et al. Effect of Restriction of the Number of Concurrently Open Records in an Electronic Health Record on Wrong-Patient Order ErrorsA Randomized Clinical Trial. JAMA 2019; 321(18): 1780-1787
https://jamanetwork.com/journals/jama/fullarticle/2733207
TJC (The Joint Commission). Safe use of health information technology. Sentinel Event Alert. Issue 54. March 31, 2015
https://www.jointcommission.org/assets/1/18/SEA_54.pdf
ONC (Office of the National Coordinator for Health Information Technology). Self-assessment: patient identification: general instructions for the SAFER Self-Assessment Guides. September 2016
https://www.healthit.gov/sites/default/files/safer/guides/safer_patient_identification.pdf
Wachter RM, Murray SG, Adler-Milstein J. Restricting the Number of Open Patient Records in the Electronic Health Record. Is the Record Half Open or Half Closed? JAMA 2019; 321(18): 1771-1773
https://jamanetwork.com/journals/jama/article-abstract/2733189