View as PDF version
Patient Safety Tip of the Week
Applying Human
Factors Concepts to Radiology
Distractions,
interruptions, workload, fatigue, System 1 vs System 2 thinking, cognitive
biases these are all factors we consider when we are doing an incident
investigation, root cause analysis, or planning a patient safety intervention.
So, its no surprise that these would play prominent roles in a new paper on
human factors in radiology. The excellent paper by Cowen et al. (Cowen
2025) has concepts and
recommendations that could easily be applied to most specialties.
They begin with a discussion on distractions
and interruptions. They note studies show radiologists are interrupted on
average every 12.1 min during daytime hours, and as frequently as every
10 min during a 12-hour night shift (see our July 1, 2014 Patient Safety Tip of the Week Interruptions and Radiologists and our November 2014 What's New in the
Patient Safety World column More Radiologist Interruptions). They further note that, in real
practice, the frequency of interruptions is likely to be even greater during
peak times and at particularly busy centers which are often staffed out of
hours by a single radiologist. They go on to discuss how the set-up of the
reporting room or environment influences the number of possible distractors.
They show a diagram of a typical open-plan reporting
room that has a radiologist(s), coordinator, and resident(s), each with a
telephone, plus clinicians waiting to discuss cases and foot traffic through
the room.
They cite research by Williams and Drew showing
that interruptions force individuals to engage in task-switching, leading to
cognitive fatigue and decreased efficiency. An interruption can cause a
radiologist to lose their place in the image review process. Eye-tracking
software utilized during the interrogation of CT images for lung nodules
demonstrated that following an interruption, the search for nodules was resumed
in the same quadrant of the image only 23.1 % of the time, which is
essentially equivalent to chance.
Potential interventions and solutions to reduce interruptions suggested:
·
isolating the reporting radiologist by
creating a sterile flight deck akin to the aviation industry with a duty
radiologist (or radiographer) taking clinician enquiries can reduce unwarranted
reporting interruptions
·
streamlining electronic vetting processes
·
electronic instant alert systems for issuing
critical reports to referring clinicians
·
use of digital
messaging systems to defer non-urgent enquiries to a
more appropriate time
Next, they note that workload
of radiologists has increased significantly in the past two decades with demand
for diagnostic imaging rising rapidly. Studies have shown that increased
workload and reporting time pressures have resulted in increased rates of error.
They cite a study by Davenport et al (Davenport
2010) that analyzed over
13,000 cross-sectional studies and found that of all the variables considered,
the most significant impact on rates of discordant reports was caseload, with
reporting discrepancy risk increasing with the number of cases read per hour.
The authors admit that potential solutions
to the workload issue are more easily suggested than they
are implemented. Hiring more radiologists, using
teleradiology for night shifts, and overlapping staff during busy hours were
some suggestions. Reducing demand via better utilization of imaging guidelines
is a difficult task.
The impacts of fatigue and burnout
were addressed. Multiple studies have demonstrated that fatigue negatively
impacts reporting accuracy in diagnostic radiology. They note the importance of
recognition of individual limitations, taking regular short breaks, and
ensuring adequate hydration during a prolonged reading session in order to maintain an optimal level of concentration and
performance. Likewise, burnout has been repeatedly shown to reduce work quality
and contribute to medical error. They also have a brief discussion about the
potential role of artificial intelligence (AI) in addressing these issues.
Then they move on to cognitive biases. They
begin with a discussion on System 1 (fast, pattern recognition) and System
2 (slow, analytical) thinking. They acknowledge that radiologists often
rely heavily on System 1 (or heuristic) thinking − rapid,
intuitive pattern recognition honed through years of training and experience.
But System 1 thinking can also lead to errors. They
note cognitive biases such as confirmation bias, anchoring, satisfaction
of search, inattention bias, and several others that may contribute to errors.
One suggested strategy to activate System 2
thinking and reduce error is use of the SCAN mnemonic for cognitive debiasing. SCAN
stands for:
S Systemic
approach
C Clinical
context/Compare with previous
A Alternative diagnoses
N Never
assume
As we noted earlier, most of the concepts in
this paper can be applied to almost any specialty. The authors have done a good
job of identifying the many factors that contribute to errors.
Some
of our prior columns on patient safety issues in the radiology suite:
·
October 16, 2007 Radiology
as a Site at High-Risk for Medication Errors
·
February 19, 2008 MRI
Safety
·
September 16, 2008 More
on Radiology as a High Risk Area
·
October 7, 2008 Lessons
from Falls....from Rehab Medicine
·
October 2008 Preventing
Infection in MRI
·
March 17, 2009 More
on MRI Safety
·
March 2009 Risk
of Burns during MRI Scans from Transdermal Drug Patches
·
August 11, 2009
The
Radiology Suite
Again!
·
January
2010 Falls in the Radiology Suite
·
August 2010 Sedation
Costs for Pediatric MRI
·
January
25, 2011 Procedural Sedation in Children
·
February
1, 2011 MRI Safety Audit
·
October
25, 2011 Renewed Focus on MRI Safety
·
March 13, 2012 Medical
Emergency Team Calls to Radiology
·
August
2012 Newest MRI Hazard: Ingested Magnets
·
October
22, 2013 How Safe Is Your Radiology Suite?
·
February
25, 2014 Joint Commission Revised Diagnostic Imaging
Requirements
·
July
2014 New MRI Risks: for Staff!
·
July 1,
2014 Interruptions and Radiologists
·
November
2014 More Radiologist Interruptions
·
October
21, 2014 The Fire Department and Your Hospital
·
June 23,
2015 Again! Mistaking Antiseptic Solution for
Radiographic Contrast
·
August
25, 2015 Checklist for Intrahospital Transport
·
March
22, 2016 Radiology
Communication Errors May Surprise You
·
August
2016 Guideline
Update for Pediatric Sedation
·
October
2016 MRI
Safety: Theres an App for That!
·
January
17, ,2017 Pediatric
MRI Safety
·
August
8, 2017 Sedation
for Pediatric MRI Rising
·
November
14, 2017 Tracking
C. diff to a CT Scanner
·
March
2018 MRI
Death a Reminder of Dangers
·
March
2018 Cardiac
Devices Safe During MRI But Spinners!?
·
April
2018 Radiologists
Get Fatigued, Too
·
May 2018
Cost
of Interrupting a Radiologist
·
November
2018 OMG!
Not My iPhone!
·
December
11, 2018 Another NMBA Accident
·
April 2,
2019 Unexpected Events During MRI
·
September
2019 New MRI Hazard: Magnetic
Eyelashes
·
October
15, 2019 Lots More on MRI Safety
·
November
5, 2019 A Near-Fatal MRI Incident
·
November
12, 2019 Patient Photographs Again
Help Radiologists
·
November
26, 2019 Pennsylvania Law on
Notifying Patients of Test Results
·
January
7, 2020 Even More Concerns About MRI
Safety
·
July 14,
2020 A Thesis on Intrahospital
Transports
·
August
25, 2020 The Off-Hours Effect in
Radiology
·
October 2020 New
Warnings on Implants and MRI
·
January 2021 New
MRI Risk: Face Masks
·
May 25, 2021 Yes, Radiologists Have
Handoffs, Too
·
June 1,
2021 Stronger Magnets, More MRI
Safety Concerns
·
November
2021 Yet Another Risk During MRI
·
January
2022 MRI
Safety Issues
·
February
2022 Managing Incidental Findings
·
June
2022 Where Are You Barcoding?
·
July 12,
2022 Radiologists Racked by
Interruptions
·
July 26,
2022 More Risks in the Radiology
Suite
·
May 2023
Factors
Associated with Radiology Diagnostic Errors
·
September 12, 2023 Radiology and
Hospital-Acquired Infections
·
October 24, 2012 Serious MRI Accident at
Unregulated MRI Center
·
November 21, 2023 Another Terrifying MRI
Accident
·
January 2024 Guns
and MRI Dont Mix
·
June 11, 2024 Nursing in the MRI Suite
·
August 13, 2024 Preventing Thermal Injury
During MRI
·
October 2024 Another
MRI Accident Reveals Gap in Oversight
·
October 2024 MRI
Special Patient Considerations
·
October 8, 2024 First Responders and MRI
·
April 22, 2025 Updated ACR Manual on MRI
Safety
References:
Cowen JE, Vigneswarand
G, Bekker J, et al. Human factors in diagnostic radiology: practical challenges
and cognitive biases. European Journal of Radiology 2025; 190: 112248
https://www.ejradiology.com/article/S0720-048X(25)00334-1/abstract
Davenport MS, Ellis JH, Khalatbari
SH, et al. Effect of work hours, caseload, shift type, and experience on
resident call performance. Aca. Radiol 2010; 17(7): 921-927
https://www.academicradiology.org/article/S1076-6332(10)00161-3/abstract
Print PDF version

http://www.patientsafetysolutions.com/